Model DI-4718B-U
Measure Anything with this 8-channel USB Data Logger and Data Acquisition System for DI-8B Amplifiers, Expandable to 128 channels
Stock
- Includes a DI-4718B-U instrument, a 6-foot USB cable, a power supply and adapter, a 3.5mm stereo jack for remote control, a USB thumb drive with WinDaq software, an NIST-traceable calibration certificate (pdf included on thumb drive), a screwdriver for signal connections. DI-8B amplifiers sold separately.
- Measures temperature, pressure, flow, current, voltage, and more using isolated 8B amplifiers. At least one 8B module is required. View the DI-8B amplifier selection guide
- Low-Cost, Portable, USB Data Logger and Data Acquisition System
- Easy signal swapping connector
- Up to 160,000 Hz Sample Throughput Rate using WinDaq Acquisition software
- Up to 160,000 Hz Sample Throughput Rate in stand-alone mode using high speed microSD card
- Eight DI-8B signal-conditioned analog inputs
- 12 to 16-bit analog-to-digital resolution (Calculate Resolution)
- Adaptable low-pass filter per channel
- Corner frequency set as a function of sampling rate
- PC-connected or stand-alone operation (Unlock code required to record more than one channel to USB flash drive)
- Supports ChannelStretch™ multi-unit synchronization expansion(Unlock Code required):
- Up to sixteen instruments
- Up to 480 kHz throughput
- Up to 128 analog channels and 112 digital ports
- Syncs with itself and USB models DI-4108, DI-4208, and DI-1120 in any combination
- Synchronization not available in stand-alone mode
- Unlock code required per device - see Accessories
- Two digital ports for remote controls
- Software support includes ready-to-run WinDaq software and documented protocol for software development in all operating systems (visit our GitHub repository for example programs)
- CE Approved
- Find out how long your data logger can record to removable flash memory with our Record Time Calculator
- 10% Education Discount
*WinDaq/Unlock required per device to use ChannelStretch™. See Accessories. Multi-unit synchronization is not available in stand-alone mode.
Description
DI-4718B-U USB Data Logger and Data Acquisition System for applications that require signal conditioning. Install up to eight DI-8B isolated signal conditioning modules on the printed circuit board using the removable front panel. Each DI-8B module protects, filters, amplifies, and isolates an input signal, providing an advanced signal conditioning solution for nearly any industrial measurement.
Model DI-4718B features 12- to 16-bit analog-to-digital resolution as a function of sample rate. Lower sampling rates deliver higher resolution readings. The maximum analog sampling throughput rate of the DI-4718B analog subsystem is 160 kHz, providing 12 bits of resolution. Resolution varies with respect to sample rate. Add up to 128 analog channels with ChannelStretch™ channel expansion, which is supported in all USB and Ethernet versions. Synchronize any USB DI-4718Bs, DI-4108s, DI-4208s, and/or DI-1120s to one PC or synchonize multiple DI-4718B Ethernet units. Acquire from as many as 128 analog and 112 digital channels at combined total throughput rates over 480 kHz.
Use a USB drive to record data in stand-alone mode. The DI-4718B can record to a USB thumb drive continuously using a circular buffer with pre-defined trigger conditions or a record-until-full approach supporting remote start/stop. A push button allows manual start/stop control over the recording process. With a flash memory card incorporating SLC technology, throughput rates up to 160 kHz can be achieved. That rate drops to 50 kHz when using pSLC card, and 20 kHz using a flash memory card incorporating MLC. The included WinDaq data acquisition software makes configuring the DI-4718B for stand-alone operation quick and intuitive. Use WinDaq to set up channels and create a reference file. That reference file can then be copied to the USB drive and used for quick setup.
Accessories
Description
DI-8B amplifiers offer the convenience to mix and match modules based upon measurement function and range to meet any application requirement, from the most simple to the most complex.
Description
Unlocks ChannelStretch™ in WinDaq and Stand-alone data logging to flash memory. Unlock code required per device. Unlock Code ONLY. No CD will be shipped. Please Note: If you are ordering this software for a device you already own, you MUST provide the serial number of your device under "Order Notes" during checkout. Please allow one (1) business day for processing.
Description
32GB 3.0 USB flash drive for stand-alone recording up to 10,000 Samples per second throughput.
Description
High-endurance 16 GB micro SD flash memory card. Recommended for recording rates between 10,000 S/s and 60,000 S/s throughput. microSD Card Reader (Part#2000352) is needed
Description
32 GB Industry-grade high capacity microSD flash memory card. Recommended for recording rates between 10,000 S/s and 40,000 S/s throughput rate and harsh environment. microSD Card Reader (Part#2000352) is needed
Description
Micro SD Card Reader with USB A interface. Hi-Speed USB 2.0 compatible transfer rates. No additional card adapters required
Description
Pair of angle mounting brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments
Description
Pair of stacking brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments
Description
Stainless steel handle for stacking brackets for DI-1000TC Series, DI-710 Series and DI-718B Series.
Description
Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Spare power supply for DI-808 and DI-4730 products.
Description
DC power connector for powering the DI-808 or DI-4718B from a source other than the provided ac adaptor.
Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for all DI-4718B data acquisition and data logger products. Includes both before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.
Description
Optional USB Cable for use with ChannelStretch™. Dual ferrite cores provide maximum protection against ground bounce that could lockup your PC's USB port during data acquisition. 20.4-inch (520 mm) overall cable length. Recommended whenever products are deployed in our ChannelStretch™ configuration.
Description
Powered 7 port USB hub to synchronize multiple USB devices. Please note: Not all DATAQ Instruments devices support synchronization - check your product datasheet or product page for detailed information. Note: Provided with a US ac adaptor only, and is not suitable for use in countries that require an ac mains connector other than the US type.
Description
16-ft USB Extension Cable. USB 2.0 Type A. Daisy chain up to 5 cables for extended length.
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DI-4718B purchase. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. Record all 8 channels to USB thumb drive and enable ChannelStretch with an Unlock Code (see Accessories) - one required PER device.
WinDaq/XL
WinDaq-to-Excel Real Time Link
Real-time data logging directly to Microsoft Excel (supports MS Office 2003 or higher). No programming required. Free Trial Version. Purchase full version on WinDaq/XL product page.
MATLAB Example Program
Program in Protocol Level
Learn how to program with MATLAB® in protocol level. Does not require MathWorks' Data Acquisition Toolbox.
WinDaq Add-ons and Utilities
Library
Library of add-on packages for WinDaq Software, such as live XY plot, FFT, Spectrogram, Meter, Gauge, Alarm, etc.
WinDaq XY Viewers
Live XY charting for WinDaq and WWB
Originally designed for GE Mining Division, these two XY plotting utilities are great tools for trouble shooting their mining equipments.
Python Example Programs
Available on GitHub
FREE Python example programs using the fully documented device protocol. All sample programs are well-commented to help you get up and running quickly.
LabView Example Programs
Available on GitHub
FREE LabView example programs using the Dataq's ActiveX Controls. All sample programs are well-commented to help you get up and running quickly.
Specifications
Analog Inputs | |
Number of Channels: | 8 configured for signal conditioned inputs |
Channel Configuration: | Defined by DI-8B Module |
Measurement Range: | Defined by DI-8B Module |
Accuracy: | ±0.25% FSR (at 1800 S/s, averaging mode) |
Input Impedance: | Defined by DI-8B Module |
Input offset voltage: | Defined by DI-8B Module |
Channel-to-channel crosstalk rejection: | -75db @ 100Ω unbalance |
Offset temperature coefficient: | 0.25µV/°C |
Digital filtering: | Standard: Conditional over-sampling Stand-alone: None |
CJC Error: | 1.5°C plus 8B Module |
Isolation (via DI-8B Modules) | |
Input-to-Output: | 1000VDC/Peak AC |
Channel-to-Channel: | 500VDC/Peak AC |
Digital Inputs | |
Ports: | 2 |
Resolution: | MOSFET switch |
Threshold Levels: | TTL-compatible |
Max applied Voltage: | 25 V DC |
Digital Ports | |
Ports: | 2 |
Maximum drain voltage: | 25 V |
Maximum sink current: | 100 mA |
Reserved Digital Inputs: | D0: WinDaq Remote Events D1: WinDaq Remote Start/Stop |
A/D Characteristics | |
Type: | Successive approximation |
Resolution: | 12 to 16-bit (Calculate) |
Conversion Time: | 69.4µs |
Scanning Characteristics | |
Max. throughput sample rate: | Standard: 160 kHz Stand-alone: 20 kHz to 160 kHz (dependent on flash memory) |
Min. throughput sample rate: | Standard: 20 Hz (2.2 samples per hour with WinDaq) Stand-alone: 0.0017 Hz |
Sample Rate Timing Accuracy: | 50 ppm |
Max. scan list size: | 9 entries |
Sample buffer size: | 2kb |
Calibration | |
Calibration cycle: | One year |
Ethernet Interface | |
Type: | 10/100Base-T |
Connector: | RJ-45 |
Protocol: | TCP/IP |
Server Type: | DHCP or Fixed IP |
Removable Memory | |
Type: | MLC, pSLC, or SLC flash memory (with USB SD card reader); USB thumb drive |
Required Format: | FAT32 |
Number of Channels: | 1 Unlock code required for 2 or more |
Rear Panel Indicators, Connections, and Controls | |
Button: | Multi-function control (Start, Stop, Save Configuration, Apply Configuration) |
USB A Connector (Drive): | USB drive for Stand-alone data logging Cannot be used concurrently with the USB interface |
Ground Lug: | Terminal for Ground |
Status LED | One multicolor LED for status indication |
Power Connector: | USB: 9 to 36 VDC, 2 watts + 8B modules Ethernet: 9 to 36 VDC, 2.5 watts + 8B modules |
Ethernet Connector: | RJ45; Optional PoE |
Front Panel Connections | |
Input connectors: | Two, removable sixteen position terminal blocks, 28 AWG min, 16 AWG max |
Radio Jack: | Standard 3.5 mm for remote control signals |
USB ChannelStretch™ Operation | |
Total Max Units: | 16 |
Max Channel Count: | 128 Analog, 112 Digital |
Max Throughput: | ≥480 kHz (higher speeds may result in data loss) |
Synchronization Conditions: | Syncs with any combination of DI-1120, DI-4108, and DI-4208 USB instruments. All synced instruments must operate at the same sample rate per channel, regardless of channel number, type, or range. All instruments must be connected to the same USB controller. The use of USB hubs are recommended to meet this requirement. |
Ethernet ChannelStretch™ Operation | |
Total Max Units: | 16 |
Max Channel Count: | 128 Analog, 112 Digital |
Max Throughput: | ≥50 kHz (higher speeds may result in data loss) |
Synchronization Conditions: | Syncs with any combination of DI-1120, DI-4108, and DI-4208 Ethernet instruments. For most accurate synchronization, all instruments should be connected to the same Ethernet switch. |
Power | |
Power Consumption: | 1.5W + 8B Modules |
Environmental | |
Operating Temperature: | 0°C to 50°C |
Operating Humidity: | 0 to 90% RH non-condensing |
Storage Temperature: | -20°C to 60°C |
Storage Humidity: | 0 to 90% RH non-condensing |
Physical Characteristics | |
Enclosure: | Aluminum base with steel wrap-around. |
Mounting: | Desktop; Bulkhead |
Dimensions: | 57/16 "D × 41/8 "W × 11/2 "H (13.81D × 10.48W × 3.81H cm.) |
Weight: | 14 oz. |
Power Requirements: | USB: 9 to 36 VDC, 2 watts + 8B modules Ethernet: 9 to 36 VDC, 2.5 watts + 8B modules |
Software Support | |
WinDaq software: | View Supported Operating Systems at https://www.dataq. com/products/windaq/windows-compatibility/ |
Programming: | Instrument protocol, ActiveX Control |
Articles
Frequency and True RMS Data Acquisition
Intelligent Oversampling Methods Extend Measurement Flexibility
Strain Gage-Based Transducer and Amplifier Selection and Calibration
How To Connect and Calibrate Thermocouples Using DI-8B47 Series Amplifiers
Connection and Calibration of Strain-Gage Based Transducers Using DI-8B38 Series Amplifiers
How To Choose Strain Gage-based Transducers for PC-based Data Acquisition Applications
Videos
Synchronous Data Acquisition
Sync up to 16 DI-4000 Series units together and record to a single file.
Similar Products
Quick Product Comparison
Model | Analog channels |
Expandable* | Measurement Range† |
Thermocouple Support |
Max Sample Rate (Hz) |
ADC Resolution |
Digital I/O |
Interface | Data Storage |
DI-4718B | 8 | Yes | A | Yes (DI-8B) | 160,000 | 12 to 16 | 2 In | USB, Ethernet | PC or USB flash |
GL240 | 10 | - | B | Yes | 100 | 16 | 4 In 4 Out | USB | PC, USB flash, Internal, Cloud |
GL840-M | 20 | Yes | B | Yes | 100 | 16 | 4 In 4 Out | USB, Ethernet | PC, USB flash, Internal, Cloud |
DI-4108 | 8 | Yes | C | No | 160,000 | 12 to 16 | 7 Bi | USB, Ethernet | PC or USB flash |
DI-4208 | 8 | Yes | D | No | 160,000 | 12 to 16 | 7 Bi | USB, Ethernet | PC or USB flash |
*Expansion capabilities dependent on model.
†Use the following chart to determine Measurement Ranges:
A | B | C | D |
Defined by DI-8B module |
±20 mV ±50 mV ±100 mV ±200 mV ±500 mV ±1 V ±2 V ±5 V ±10 V ±20 V ±50 V ±100 V 1-5 V Thermocouple More (dependent on accessories) |
±200 mV ±500 mV ±1 V ±2 V ±5 V ±10 V |
±2 V ±5 V ±10 V ±20 V ±50 V ±100 V |