  • Includes a DI-4718B-U instrument, a 6-foot USB cable, a power supply and adapter, a 3.5mm stereo jack for remote control, a USB thumb drive with WinDaq software, an NIST-traceable calibration certificate (pdf included on thumb drive), a screwdriver for signal connections. DI-8B amplifiers sold separately.
  • Measures temperature, pressure, flow, current, voltage, and more using isolated 8B amplifiers. At least one 8B module is required. View the DI-8B amplifier selection guide
  • Low-Cost, Portable, USB Data Logger and Data Acquisition System
  • Easy signal swapping connector
  • Up to 160,000 Hz Sample Throughput Rate using WinDaq Acquisition software
  • Up to 160,000 Hz Sample Throughput Rate in stand-alone mode using high speed microSD card
  • Eight DI-8B signal-conditioned analog inputs
  • 12 to 16-bit analog-to-digital resolution (Calculate Resolution)
  • Adaptable low-pass filter per channel
    • Corner frequency set as a function of sampling rate
  • PC-connected or stand-alone operation (Unlock code required to record more than one channel to USB flash drive)
  • Supports ChannelStretch™ multi-unit synchronization expansion(Unlock Code required):
    • Up to sixteen instruments
    • Up to 480 kHz throughput
    • Up to 128 analog channels and 112 digital ports
    • Syncs with itself and USB models DI-4108, DI-4208, and DI-1120 in any combination
    • Synchronization not available in stand-alone mode
    • Unlock code required per device - see Accessories
  • Two digital ports for remote controls
  • Software support includes ready-to-run WinDaq software and documented protocol for software development in all operating systems (visit our GitHub repository for example programs)
  • CE Approved
  • Find out how long your data logger can record to removable flash memory with our Record Time Calculator
  • 10% Education Discount

*WinDaq/Unlock required per device to use ChannelStretch™. See Accessories. Multi-unit synchronization is not available in stand-alone mode.

Tweet this page Like this product on Facebook Share this page on LinkedIn Email this page
DI-4718B DAQ and Data Logger
DI-4718B DAQ and Data Logger Front Panel DI-4718B DAQ and Data Logger Rear Panel DI-4718B DAQ and Data Logger
This data logger features 8 analog input channelsThis data acquisition system is expandable with ChannelStretch allowing you to connect multiple units and synchronize data recording.This data acquisition system has two digital inputs
This data acquisition system can sample and record data at up to 160,000 sample per second throughputThis data logger has a USB interfaceThis data logger can save data directly to a USB flash drive
10% Education DiscountThis data acquisition system has a 30-day Money back guaranteeThis data logger is manufactured in the United States of America

Description

DI-4718B-U USB Data Logger and Data Acquisition System for applications that require signal conditioning. Install up to eight DI-8B isolated signal conditioning modules on the printed circuit board using the removable front panel. Each DI-8B module protects, filters, amplifies, and isolates an input signal, providing an advanced signal conditioning solution for nearly any industrial measurement.

Model DI-4718B features 12- to 16-bit analog-to-digital resolution as a function of sample rate. Lower sampling rates deliver higher resolution readings. The maximum analog sampling throughput rate of the DI-4718B analog subsystem is 160 kHz, providing 12 bits of resolution. Resolution varies with respect to sample rate. Add up to 128 analog channels with ChannelStretch™ channel expansion, which is supported in all USB and Ethernet versions. Synchronize any USB DI-4718Bs, DI-4108s, DI-4208s, and/or DI-1120s to one PC or synchonize multiple DI-4718B Ethernet units. Acquire from as many as 128 analog and 112 digital channels at combined total throughput rates over 480 kHz.

Use a USB drive to record data in stand-alone mode. The DI-4718B can record to a USB thumb drive continuously using a circular buffer with pre-defined trigger conditions or a record-until-full approach supporting remote start/stop. A push button allows manual start/stop control over the recording process. With a flash memory card incorporating SLC technology, throughput rates up to 160 kHz can be achieved. That rate drops to 50 kHz when using pSLC card, and 20 kHz using a flash memory card incorporating MLC. The included WinDaq data acquisition software makes configuring the DI-4718B for stand-alone operation quick and intuitive. Use WinDaq to set up channels and create a reference file. That reference file can then be copied to the USB drive and used for quick setup.

Accessories

DI-8B Amplifiers

Signal Conditioning Modules

$116–$198 ea.
DI-8B Amplifier Modules

Description

DI-8B amplifiers offer the convenience to mix and match modules based upon measurement function and range to meet any application requirement, from the most simple to the most complex.

SA-Enabled-4718B

DI-4718B Unlock Code

$200.00
WinDaq Unlock Code

Description

Unlocks ChannelStretch™ in WinDaq and Stand-alone data logging to flash memory. Unlock code required per device. Unlock Code ONLY. No CD will be shipped. Please Note: If you are ordering this software for a device you already own, you MUST provide the serial number of your device under "Order Notes" during checkout. Please allow one (1) business day for processing.

101014-Flash

32GB USB Flash

$20.00
32GB USB Flash Drive

Description

32GB 3.0 USB flash drive for stand-alone recording up to 10,000 Samples per second throughput.

101014-16-MS

16GB high-endurance pSLC microSD Card (High Endurance)

$49.00
16GB Mid Speed Micro SD Card

Description

High-endurance 16 GB micro SD flash memory card. Recommended for recording rates between 10,000 S/s and 60,000 S/s throughput. microSD Card Reader (Part#2000352) is needed

101014-32-HS

32GB Industrial-Grade microSD Card (High-Endurance)

$99
32GB Mid Speeed MicroSD Card

Description

32 GB Industry-grade high capacity microSD flash memory card. Recommended for recording rates between 10,000 S/s and 40,000 S/s throughput rate and harsh environment. microSD Card Reader (Part#2000352) is needed

2000352

microSD Card Reader

$25
Micro SD Card Reader

Description

Micro SD Card Reader with USB A interface. Hi-Speed USB 2.0 compatible transfer rates. No additional card adapters required

100947-1

Mounting Brackets

$49.00
Right-angle Mounting Brackets

Description

Pair of angle mounting brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments

SB-1000

Stacking Brackets

$49.00
Bracket and Handle

Description

Pair of stacking brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments

100690

Handle

$39.00
Bracket and Handle

Description

Stainless steel handle for stacking brackets for DI-1000TC Series, DI-710 Series and DI-718B Series.

100995-MCVR

Screw Terminal Block (Top)

$10.00
16-port screw terminal block

Description

Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

100995-MCVW

Screw Terminal Block (Bottom)

$10.00
16-port screw terminal block

Description

Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.

101018

Power Supply

$39.00
Spare power supply for DI-808 Web-based Data Logger

Description

Spare power supply for DI-808 and DI-4730 products.

100480

Power Cable

$10.00
Power Cable

Description

Power cable (US) for power supply.

200300

Power Connector

$5.00
Power Connector

Description

DC power connector for powering the DI-808 or DI-4718B from a source other than the provided ac adaptor.

NIST-4718B-CAL

Calibration Certificate

$95.00
NIST Calibration Certificate

Description

Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for all DI-4718B data acquisition and data logger products. Includes both before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.

CBL-100803

USB Cable

$6.99
Dual Ferrite USB cable for ChannelStretch

Description

Optional USB Cable for use with ChannelStretch™. Dual ferrite cores provide maximum protection against ground bounce that could lockup your PC's USB port during data acquisition. 20.4-inch (520 mm) overall cable length. Recommended whenever products are deployed in our ChannelStretch™ configuration.

2000310

7 Port USB Hub

$49.00
USB Hub

Description

Powered 7 port USB hub to synchronize multiple USB devices. Please note: Not all DATAQ Instruments devices support synchronization - check your product datasheet or product page for detailed information. Note: Provided with a US ac adaptor only, and is not suitable for use in countries that require an ac mains connector other than the US type.

CBL-100641-16

USB Extension Cable

$29.00
16-foot USB 2.0 extension cable.

Description

16-ft USB Extension Cable. USB 2.0 Type A. Daisy chain up to 5 cables for extended length.

Software

WinDaq

Data Acquisition Recording and Playback Software

Included FREE with your DI-4718B purchase. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. Record all 8 channels to USB thumb drive and enable ChannelStretch with an Unlock Code (see Accessories) - one required PER device.

WinDaq Data Acquisition Software

WinDaq/XL

WinDaq-to-Excel Real Time Link

Real-time data logging directly to Microsoft Excel (supports MS Office 2003 or higher). No programming required. Free Trial Version. Purchase full version on WinDaq/XL product page.

WinDaq Data Acquisition Software

MATLAB Example Program

Program in Protocol Level

Learn how to program with MATLAB® in protocol level. Does not require MathWorks' Data Acquisition Toolbox.

DATAQ SDK MATLAB DOT NET

WinDaq Add-ons and Utilities

Library

Library of add-on packages for WinDaq Software, such as live XY plot, FFT, Spectrogram, Meter, Gauge, Alarm, etc.

WinDaq Data Acquisition Add-on Software

WinDaq XY Viewers

Live XY charting for WinDaq and WWB

Free

Originally designed for GE Mining Division, these two XY plotting utilities are great tools for trouble shooting their mining equipments.

WinDaq Data Acquisition XY Viewerse

Python Example Programs

Available on GitHub

FREE Python example programs using the fully documented device protocol. All sample programs are well-commented to help you get up and running quickly.

DATAQ Python Example Programs

LabView Example Programs

Available on GitHub

FREE LabView example programs using the Dataq's ActiveX Controls. All sample programs are well-commented to help you get up and running quickly.

DATAQ LabView Example Programs

Specifications

Analog Inputs
Number of Channels: 8 configured for signal conditioned inputs
Channel Configuration: Defined by DI-8B Module
Measurement Range: Defined by DI-8B Module
Accuracy: ±0.25% FSR (at 1800 S/s, averaging mode)
Input Impedance: Defined by DI-8B Module
Input offset voltage: Defined by DI-8B Module
Channel-to-channel crosstalk rejection: -75db @ 100Ω unbalance
Offset temperature coefficient: 0.25µV/°C
Digital filtering: Standard: Conditional over-sampling
Stand-alone: None
CJC Error: 1.5°C plus 8B Module
Isolation (via DI-8B Modules)
Input-to-Output: 1000VDC/Peak AC
Channel-to-Channel: 500VDC/Peak AC
Digital Inputs
Ports: 2
Resolution: MOSFET switch
Threshold Levels: TTL-compatible
Max applied Voltage: 25 V DC
Digital Ports
Ports: 2
Maximum drain voltage: 25 V
Maximum sink current: 100 mA
Reserved Digital Inputs: D0: WinDaq Remote Events
D1: WinDaq Remote Start/Stop
A/D Characteristics
Type: Successive approximation
Resolution: 12 to 16-bit (Calculate)
Conversion Time: 69.4µs
Scanning Characteristics
Max. throughput sample rate: Standard: 160 kHz
Stand-alone: 20 kHz to 160 kHz (dependent on flash memory)
Min. throughput sample rate: Standard: 20 Hz (2.2 samples per hour with WinDaq)
Stand-alone: 0.0017 Hz
Sample Rate Timing Accuracy: 50 ppm
Max. scan list size: 9 entries
Sample buffer size: 2kb
Calibration
Calibration cycle: One year
Ethernet Interface
Type: 10/100Base-T
Connector: RJ-45
Protocol: TCP/IP
Server Type: DHCP or Fixed IP
Removable Memory
Type: MLC, pSLC, or SLC flash memory (with USB SD card reader); USB thumb drive
Required Format: FAT32
Number of Channels: 1
Unlock code required for 2 or more
Rear Panel Indicators, Connections, and Controls
Button: Multi-function control (Start, Stop, Save Configuration, Apply Configuration)
USB A Connector (Drive): USB drive for Stand-alone data logging
Cannot be used concurrently with the USB interface
Ground Lug: Terminal for Ground
Status LED One multicolor LED for status indication
Power Connector: USB: 9 to 36 VDC, 2 watts + 8B modules
Ethernet: 9 to 36 VDC, 2.5 watts + 8B modules
Ethernet Connector: RJ45; Optional PoE
Front Panel Connections
Input connectors: Two, removable sixteen position terminal blocks, 28 AWG min, 16 AWG max
Radio Jack: Standard 3.5 mm for remote control signals
USB ChannelStretch™ Operation
Total Max Units: 16
Max Channel Count: 128 Analog, 112 Digital
Max Throughput: ≥480 kHz (higher speeds may result in data loss)
Synchronization Conditions: Syncs with any combination of DI-1120, DI-4108, and DI-4208 USB instruments.
All synced instruments must operate at the same sample rate per channel, regardless of channel number, type, or range.
All instruments must be connected to the same USB controller. The use of USB hubs are recommended to meet this requirement.
Ethernet ChannelStretch™ Operation
Total Max Units: 16
Max Channel Count: 128 Analog, 112 Digital
Max Throughput: ≥50 kHz (higher speeds may result in data loss)
Synchronization Conditions: Syncs with any combination of DI-1120, DI-4108, and DI-4208 Ethernet instruments.
For most accurate synchronization, all instruments should be connected to the same Ethernet switch.
Power
Power Consumption: 1.5W + 8B Modules
Environmental
Operating Temperature: 0°C to 50°C
Operating Humidity: 0 to 90% RH non-condensing
Storage Temperature: -20°C to 60°C
Storage Humidity: 0 to 90% RH non-condensing
Physical Characteristics
Enclosure: Aluminum base with steel wrap-around.
Mounting: Desktop; Bulkhead
Dimensions: 57/16 "D × 41/8 "W × 11/2 "H
(13.81D × 10.48W × 3.81H cm.)
Weight: 14 oz.
Power Requirements: USB: 9 to 36 VDC, 2 watts + 8B modules
Ethernet: 9 to 36 VDC, 2.5 watts + 8B modules
Software Support
WinDaq software: View Supported Operating Systems at https://www.dataq. com/products/windaq/windows-compatibility/
Programming: Instrument protocol, ActiveX Control

Videos

Introducing WinDaq's RPM channel
WinDaq RPM channel

See how WinDaq's RPM channel work.
Live View of Stand-alone data logger recording session
Live Viewer

Take a sneak peek (via ethernet) at data being recorded to the USB flash drive.
Synchronous Data Acquisition Using the DI-2108-P USB DAQ
Synchronous Data Acquisition

Sync up to 16 DI-4000 Series units together and record to a single file.
Stand-alone data logger configuration using the WinDaq Dashboard Utility
Stand-alone Setup

Learn how to configure your data logger to record to USB thumb drive.
Exporting Data to Excel
Export data to Excel

Learn how to export data from WinDaq Waveform Browser to Microsoft Excel.
Introduction to WinDaq Data Acquisition Software
WinDaq Data Acquisition Software

Introduction to WinDaq Data Acquisition Software.

Similar Products

Quick Product Comparison

Model Analog
channels
Expandable* Measurement
Range
Thermocouple
Support
Max Sample
Rate (Hz)
ADC
Resolution
Digital
I/O
Interface Data Storage
DI-4718B 8 Yes A Yes (DI-8B) 160,000 12 to 16 2 In USB, Ethernet PC or USB flash
GL240 10 - B Yes 100 16 4 In 4 Out USB PC, USB flash, Internal, Cloud
GL840-M 20 Yes B Yes 100 16 4 In 4 Out USB, Ethernet PC, USB flash, Internal, Cloud
DI-4108 8 Yes C No 160,000 12 to 16 7 Bi USB, Ethernet PC or USB flash
DI-4208 8 Yes D No 160,000 12 to 16 7 Bi USB, Ethernet PC or USB flash

*Expansion capabilities dependent on model.

Use the following chart to determine Measurement Ranges:

A B C D
Defined by
DI-8B module
±20 mV
±50 mV
±100 mV
±200 mV
±500 mV
±1 V
±2 V
±5 V
±10 V
±20 V
±50 V
±100 V
1-5 V
Thermocouple
More
(dependent on accessories)
±200 mV
±500 mV
±1 V
±2 V
±5 V
±10 V
±2 V
±5 V
±10 V
±20 V
±50 V
±100 V

 

Reviews